Built for High-Density Capacity

Data center equipment is getting smaller and more powerful. With the arrival of high-density blade servers means that computing power that once used to fit in several cabinets can now fit in a single rack. Our high density hosting packages are designed to scale this massive increase of computing power in the same footprint. Instead of less than 4kW per rack, our high density solutions now draw upwards of 20kW per rack. High density hosting can be attractive for companies with intensive processing requirements, in industries such as banking, pharmaceutical and gaming. A 20kW rack housing blade-servers with built-in switching can replace up to 20 cabinets. This gives you a smaller footprint with more reliability and simpler management, and ultimately lower installation and operational costs.

Diesel Generators
Trane Chillers
Diesel-Generators_20150916-1080x675-1024x640

Our infrastructure is solid

Located within minutes from Hartsfield–Jackson Atlanta International Airport and downtown Atlanta, Godby Road data center is a purpose-built, 48,000 sq. ft., one story facility built slab on grade with a steel frame and brick façade. 

 

Connectivity to the Internet is assured by multiple dark fiber rings into our data centers Telco rooms through diverse entry points. Multi-gigabit connectivity is used to link our data centers to each other and to connect upstream providers to our own network. Our team monitors the data center and network operations 24 hours a day, 7 days a week, 365 days per year.

 

 

Facility

  • 5 Acres Land w/ Perimeter Security Fencing
  • 48k SF Building
  • 16k SF Raised Floor 24” UnderFloor
  • Large Office Space
  • Over-sized loading dock
  • Minutes from Hartsfield-Jackson Atlanta International Airport

Power

  • Dual Ga Power Grid Feeds from DIVERSE Grids
  • Two (2) 3000AMP Services
  • Two (2) 2.5MegaWatts Committed Power
  • UPS N+1 (2.3MegaWatts Total)
  • Two (2) 750kVA (400KVA units being replaced)
  • Two (2) 400kVA

Generators N+1 (2 MegaWatts Total)

  • 2x 1 MegaWatt
  • Stubbed for 2 additional Generators in future
  • Diesel Fuel: 10k Gallon Fuel Tank (Underground)

Dual Entry (E + W) Fiber

  • Zayo
  • ATT (4 Diverse Central Office Routes)
  • TWTC/Level3

Security

  • Perimeter Secured Fence
  • 24x7 Security Guard
  • Card Readers
  • BioMetric
  • Cameras

Air Conditioning  N+1

  • Trane Centrifugal Chillers (900 ton Total)
  • Dedicated Chilled Water Cooling System (50 Ton Total)
  • Dedicated 15k Gallon Water Tank (1 week without city water)
  • Smoke Detection above and below floors
Cooling Details
Cooling-Details_20150916-3-1080x675-1024x640
Cooling-Details_20150916-1080x675-1024x640